Delta4 Software Modules

A choice of software options to expand the functionality of your Delta4 Phantom

Software functionality to perform acquisition, presentation and analysis of the dose distribution and the delivery sequence in rotational therapy modalities such as Varian RapidArc, Elekta VMAT and Philips SmartArc.

REF:

Delta4 VMAT QA module

SDOS101-11

Software functionality to perform acquisition, presentation and analysis of the dose distribution and delivery sequence in Halcyon.

REF:

Delta4 Halcyon QA module

SDOS101-13

Software functionality to perform acquisition, presentation and analysis of the dose distribution and delivery sequence in tomotherapy.

REF:

Delta4 Tomotherapy QA module

SDOS101-12

  • Calculation of full 3D volume dose distribution and deviations.

  • Display of distribution and deviations in Sagittal, Coronal and Transverse planes.

  • Calculation of Dose Volume Histograms (DVH) for patient structures.

  • The calculation uses either TPS Plan Data or Accelerator Beam Data.

  • DICOM STRUCTURE import function.

REF:

Delta4 DVH software module

SDOS101-03

Includes all functionality of Delta 4DVH, plus:

  • Automated analysis of deviations with respect to their clinical relevance.

  • Gamma, Dose Deviation and Distance to Agreement analysis for selected structures.

  • Structures are classified as Target or Organs at Risk
    with relevant acceptance criteria for different types of structures and different types of treatment cases.

REF:

Delta4 DVH Professional software module

SDOS101-06

Includes all functionality of Delta 4DVH Professional, plus:

  • Calculation of the delivered dose in the Patient based on high accuracy dose measurements in the Delta4PT phantom.

  • Display of 3D dose distribution in the Patient Anatomy and DVH calculation in the Patient Structure set.

  • Import of CT images.

REF:

Delta4 DVH Anatomy software module

SDOS101-08

Advanced machine QA in 3D and 4D for the periodical checks and analysis of accelerator beam constancy.


  • Dynamic checks include linac start-up with parameterization, start-up reproducibility.

  • Static checks include dose output, flatness, symmetry and energy constancy.

  • Automated MLC picket fence test with absolute and relative positon deviations in various gantry angles.

REF:

Delta4 Machine QA module

SDOS101-05

Downloads

Delta4 Phantom+ Brochure

Looking for a data sheet, paper or user manual? Please contact us