Delta4 Phantom+

The Delta4 Phantom+ is the only system that actually measures the dose distribution in the isocentric region.

The Delta4 Phantom+ system offers the most accurate and most efficient verification of your IMRT, VMAT and TomoTherapy plans.


Now Completely Wireless


  • Integrated Wi-Fi and Battery operation keeps all cords away

  • New generation stable p-type detectors eliminates re-calibration

  • Absolute dose also available with ion chamber

  • Easy to move from trolley to couch with no lifting required

  • Measure where it really matters - detectors in the target region

  • Instant approval of plans


The Delta4 Phantom+ system is the only system that actually measures the dose distribution in the isocentric region. You can therefore instantly approve the plans as you know how much dose that is delivered in the target and the OAR's.

  • PMMA measuring phantom with insert for ion chamber

  • Wi-Fi communication

  • 3D detector arrays with 1069 detectors

  • Delta4 Basic software for acquisition of data and analysing functions:

  • Dose, dose deviation, distance to agreement and gamma index

  • Main functionality for rotation therapy QA 

  • Calculation of full 3D volume dose distribution and deviation.

  • Display of distribution and deviation in sagittal, coronal and transversal planes.

  • Calculation of Dose Volume Histograms (DVH) for patient structures. The calculation is based on TPS- or beam-data.

REF:

Thumb_RT-4543C Arm Shuttle.jpg
Delta4 Phantom+ PMMA

SDOS101-54

  • Plastic Water® measuring phantom with insert for ion chamber 

  • Wi-Fi communication

  • 3D detector arrays with 1069 detectors

  • Delta4 Basic software for acquisition of data and analysing functions:

  • Dose, dose deviation, distance to agreement and gamma index

  • Main functionality for rotation therapy QA

  • Calculation of full 3D volume dose distribution and deviation.

  • Display of distribution and deviation in sagittal, coronal and transversal planes.

  • Calculation of Dose Volume Histograms (DVH) for patient structures. The calculation is based on TPS- or beam-data.

REF:

Thumb_RT-4543C Arm Shuttle.jpg
Delta4 Phantom+ Plastic Water®

SDOS101-56

Trolley for easy and ergonomic placement of the Delta4 Phantom+ system on the treatment couch without any manual lifting.

REF:

Thumb_RT-4543C Arm Shuttle.jpg
Delta4 Phantom+ Trolley

SDOS102-04